Heidenhain Workpiece touch probes TS740
Feature
With the TS 740, the deflection of the stylus is measured by several pressure sensors that are arranged between the contact plate and the probe housing. When probing a workpiece, the stylus is deflected and a force acts on the sensors. the signals generated are processed, and the trigger signal is produced. The relatively low probing forces provide high probe accuracy and repeatability, while offering precise trigger characteristics in all directions.
specification
|
Workpiece touch probe |
Radio and infrared |
Infrared |
||
|
TS 460 |
TS 642 |
TS 740 |
||
|
Probe accuracy |
≤±5 μm with use of the standard stylus T404 |
≤ ±1 μm with use of the standard stylus T404 |
||
|
Probe repeatability Repeated probing from one direction |
2 s ≤ 1 μm at a probing velocity of 1 m/min Typical values: |
2 s ≤ 0.25 μm |
||
|
Deflection of probe |
≤ 5 mm in all directions (with stylus length L = 40 mm) contact |
|||
|
Deflection force |
Axial: Approx. 8 N Radial: Approx. 1 N |
Axial: Approx. 0.6 N Radial: Approx. 0.2 N |
||
|
Probing velocity |
† 5 m/min |
† 0.25 m/min |
||
|
Collision protection |
Optional |
– |
||
|
Protection EN 60529 |
IP68 |
|||
|
Operating temperature |
10 °C to 40 °C |
|||
|
Storage temperature |
–20 °C to 70 °C |
|||
|
Mass without taper shank |
» 0.2 kg |
Approx. 1.1 kg |
||
|
Fastening* |
• With taper shank |
• With taper shank |
||
|
Signal transmission |
Radio and infrared transmission (selectable) with 360° range to SE |
Infrared transmission with 360° range |
||
|
Transmission angle of infrared signal* |
0° or +30° |
|||
|
Interface* |
HTL, EnDat 2.2 |
HTL |
||
|
Transceiver unit* |
• SE 661/SE 660 for radio and infrared transmission • SE 642 for infrared transmission • SE 540 for infrared transmission; for integration in the spindle head |
SE 540, SE 642, or SE 660 (only infrared) |
SE 540 or SE 642 |
|
|
TS switch-on/off |
Radio or infrared signal (selectable) from SE |
Via switch in the taper shank or infrared signal from SE |
Infrared signal from SE |
|
|
Voltage supply |
Two rechargeable or nonrecharge- able batteries, 1 V to 4 V each, size 1/2 AA or size LR2 |
Two rechargeable or nonrechargeable batteries, 1 V to 4 V each, size C or size A4) |
||
|
Operating time |
Typically 90 h3) with alkaline batteries (included in delivery); Typically 400 h3) possible with lithium batteries |
Typically 400 h with alkaline batteries (included in delivery) Typically 800 h possible with lithium batteries |
Typically 220 h with alkaline batteries (included in delivery) Typically 500 h possible with lithium batteries |
|